Radiology - Technology Information Portal
Wednesday, 17 April 2024
• Welcome to Radiology-TIP.com!
     • Sign in / Create account
 
 'Anode' 
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'Anode' found in 1 term [
] and 5 definitions [
]
Result Pages :
Anode
The anode is the positive terminal of an x-ray tube, usually consisting of a tungsten block embedded in a copper stem. Electrons flow from the cathode toward the anode and the anode emits x-rays from the focal spot.
X-Ray Tube
X-ray tubes are devices for the production of x-rays. X-ray tubes consist of an evacuated glass vessel and two electrodes. An electrical current with very high voltage passes across the tube and accelerates electrons emitted by thermionic emission from a tungsten filament (cathode also called electron gun) towards the anode target. The electrons collide with the anode and this deceleration generates x-rays (bremsstrahlung).
The high vacuum allows the electron beam an unimpeded passage. The electron beam heats the anode (usually copper), which is cooled by water to prevent melting. A copper target emits x-rays with a characteristic wavelength. Other used metals soften or harden the x-ray beam.
The x-rays pass through a very thin beryllium (Be) foil. This beryllium window absorbs a high amount of the elastically scattered electrons (produced by the target) and allows the radiation to get out of the tube without substantial absorption.
In conventional x-ray tubes, the anode is also the target. In nanofocus and microfocus x-ray tubes, the electron beam is transmitted through a hole in the anode where it is then focused onto a small spot on the target.

See also X-Ray Tube Housing, Fine Focus X-Ray Tube, Transformer, Diode, Digital to Analog Converter and Angular Response.
Focal Spot
The focal spot is the point where the electron beam impinges on the tube anode and from which x-rays are emitted. The size of the focal spot is determined by the size of the filament and cathode, which is determined by the manufacturer.
Most x-ray tubes have more than one focal spot size. The size of the focal spot has influence on spatial resolution. The smaller the focal spot, the better the limiting spatial resolution of the x-ray system, especially in magnification mammography. The use of a small focal spot concentrates heat onto a smaller portion of the anode therefore, more heat is generated and a longer cooling time is necessary.
Anion
An anion is a negative charged ion; the atom has more electrons than protons. Anions are attracted from the positively charged anode. This is a basic part for producing radiation in the x-ray tube.
Ion
An ion is an atomic particle that is electrically charged, either negatively or positively by loss or addition of one or more electrons. The simplest ions are for example hydrogen ions (a proton, H+), or an alpha particle (helium ion, He2+).
Positively-charged ions have fewer electrons than protons. They are cations due to the attraction to cathodes.
Negatively charged ions have more electrons in the electron shells than they have protons in the core. Due to their attraction to anodes they are named anions.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]