Radiology - Technology Information Portal
Thursday, 25 April 2024
• Welcome to Radiology-TIP.com!
     • Sign in / Create account
 
 'Conventional Radiography' p2
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'Conventional Radiography' found in 1 term [
] and 8 definitions [
], (+ 1 Boolean[
] results
Result Pages :
Direct Exposure Film
Direct exposure films are highly sensitive to the direct effect of x-rays rather than in combination with an intensifying screen. However, a film is a relatively inefficient radiation detector and requires relatively high radiation exposure. The use of rectangular collimation and the highest speed films reduce radiation exposure.

See also Conventional Radiography.
Radiography
Radiography is a synonym for the examination of the structure of materials by nondestructive methods, for example with radiation. Radiography is used for both medical and industrial applications.
Autoradiography describes the imaging of an object using radiations produced by the radioactive decay of nuclides in the object.
Sometimes, imaging modalities without use of radiation such as MRI and ultrasound are grouped in radiography due to the fact that the radiology staff handles different forms of medical imaging. Treatment using radiation is known as radiotherapy.

See also Diagnostic Imaging and Conventional Radiography.
X-Ray Film
An x-ray film is a photographic film used to generate a visual x-ray image. X-ray films are rarely used as the only radiation detector. Commonly they are used in conjunction with intensifying screens placed in the film cassette, because high resolution films have a poor sensitivity to x-rays. At direct film exposure, only a small amount of x-ray photons will be absorbed and react with the film emulsion. An intensifying screen contains scintillating materials to convert x-ray radiation into light or lows electromagnetic energies.
X-ray films provide very good spatial resolution and contrast, but need long exposures times and chemical processing.

See also Conventional Radiography and Digital Radiography.
Imaging Plate
An imaging plate is used in computed radiography (CR) instead of a conventional film cassette.
The imaging plate is coated with photostimulable phosphors. The phosphor layer is doped with special substances to alter the crystalline structure and physical properties. After radiation, the enhanced phosphor material absorbs and stores x-ray energy in gaps of the crystal structure, building a latent image.
Usually, the storage phosphors are stimulated with a low-energy laser to release visible light at each point of x-ray absorption. To read-out the image, the plate is inserted into a computed radiography scanner. The scanning laser beam causes the electrons to relax to lower energy levels, emitting light that is captured by a photo-multiplier tube and converted into an electrical signal. The electronic signal is then converted to digital data and can be displayed on laser-printed films, workstations, transmitted to remote systems, and stored digitally.
The CR units automatically erase the image plate after the complete scan. Phosphor imaging plates, like film, are stored in cassette format and can be re-used very often if they are handled carefully. Existing conventional x-ray equipment, from generators to x-ray tubes and examination systems, can be used with imaging plates.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]