 'Detector' p2
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'Detector' found in 1 term [
] and 40 definitions [
]
Result Pages :
Annihilation Coincidence Detection
(ACD) Caused by positron decay and positron annihilation two photons are emitted each with an energy of 511 keV in opposite directions. The simultaneous detection of these two photons, by two detectors indicates that a positron annihilation occurred at the line of response (LOR), the path between the two detectors.
In PET imaging the annihilation coincidence detection is used to localize the tracer, e.g. F18.

See also Positron Decay and Electron Positron Annihilation.
Calibration Factor
The calibration factor helps to convert between the measured value of a parameter and the actual value of that parameter in a system.
This normalization is necessary in cases where detectors and sensors do not directly sample a parameter, for example the radiation energy is measured by a detector that produces an electrical pulse whose total charge is proportional to the supplied radiation.
Computed Tomography
(CT or CAT scan) Computed tomography is a diagnostic imaging technique, previously also known as computerized axial tomography (CAT), computer-assisted tomography (CAT), computerized tomographic imaging, and reconstructive tomography (RT).
A CT scan is based on the measurement of the amount of energy that a tissue absorbs as a beam of radiation passes through it from a source to a detector. As the patient table moves through the CT scanner, the CT tube rotates within the circular opening and the set of x-ray detectors rotate in synchrony. The narrow, fan-shaped x-ray beam has widths ranging from 1 to 20 mm. The large number of accurate measurements with precisely controlled geometry is transformed by mathematical procedures to image data. Corresponding to CT slices of a certain thickness, a series of two-dimensional cross-sectional images is created.
A CT is acquired in the axial plane, while coronal and sagittal images can be rendered by computer reconstruction. Although a conventional radiography provides higher resolution for bone x-rays, CT can generate much more detailed images of the soft tissues. Contrast agents are often used for enhanced delineation of anatomy and allow additional 3D reconstructions of arteries and veins.
CT scans use a relatively high amount of ionizing radiation compared to conventional x-ray imaging procedures. Due to widespread use of CT imaging in medicine, the exposure to radiation from CT scans is an important issue. To put this into perspective, the FDA considers the risk of absorbed x-rays from CT scans to be very small. Even so, the FDA recommends avoiding unnecessary exposure to radiation during diagnostic imaging procedures, especially for children.
CT is also used in other than medical fields, such as nondestructive testing of materials including rock, bone, ceramic, metal and soft tissue.

See also Contrast Enhanced Computed Tomography.
Demodulator
Another term for detector, by analogy to broadcast radio receivers. Other terms used for devices of this type include modulators, phase sensitive detector and mixers.
Line Of Response
(LOR) Line of response is in PET imaging the path between two detectors used to localize the tracer. Based on the size of the detectors - volume of response (VOR) is used instead of LOR.

See also Annihilation Coincidence Detection.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups