Radiology - Technology Information Portal
Friday, 29 March 2024
• Welcome to Radiology-TIP.com!
     • Sign in / Create account
 
 'Display Field of View' 
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'Display Field of View' found in 1 term [
] and 1 definition [
], (+ 3 Boolean[
] results
Result Pages :
Display Field of View
(DFOV / RFOV) The display field of view is a selectable scan factor measured from the center of the patient to the most distant located edge of the patient.
Display
A display is a computer monitor that shows the processed data from the scanned area. Displays can be black-and-white or color, small or large depending upon the model and price of the machine.

See also Display Field of View, Display Matrix, Window Width, Bit Range, Hounsfield Scale, Interpolation, Minimum Intensity Projection, and Printer.
CT Number
(Computed tomography number) The CT number is a selectable scan factor based on the Hounsfield scale. Each elemental region of the CT image (pixel) is expressed in terms of Hounsfield units (HU) corresponding to the x-ray attenuation (or tissue density).
CT numbers are displayed as gray-scale pixels on the viewing monitor. White represents pixels with higher CT numbers (bone). Varying shades of gray are assigned to intermediate CT numbers e.g., soft tissues, fluid and fat. Black represents regions with lower CT numbers like lungs and air-filled organs.
Pixel
A pixel is a picture element (pix, abbreviation of pictures + element). Tomographic images are composed of several pixels; the pixel size is determined by the used field of view and the number of elements in the display image matrix. The corresponding size of the pixel may be smaller than the actual spatial resolution.
Pixels do not have a fixed size; their diameters are generally measured in micrometers (microns). Although the pixel is not a unit of measurement itself, pixels are often used to measure the resolution (or sharpness) of images. As a hypothetical example, a 600 x 1000 pixel image has 4 times the pixel density and is thus 4 times sharper than a 300 x 500 pixel image, assuming the two images have the same physical size.
Zoom Reconstruction
A zoom reconstruction is the enlarged reconstruction of a part of an image. A zoom reconstruction uses the raw data of a scan. Zooming or targeting requires the operator to manipulate the displayed field of view.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]