 'Dose' p12
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'Dose' found in 21 terms [
] and 45 definitions [
]
Result Pages :
Koning Corporation
www.koningcorporation.com The Koning CT, a Cone Beam CT, provides high spatial and true isotropic resolution at lower dose levels than current CT units. The Koning CT for Breast was introduced at RSNA 2006 and is not cleared for sale in the USA.

Related Product Lines:
CT Systems:

www.koningcorporation.com/Product.html
Contact Information
MAIL
Koning Corporation
Lennox Tech Enterprise Center
150 Lucius Gordon Drive, Suite #112
West Henrietta
New York 14586
USA
PHONE
+1-585-214-2459
FAX
+1-585-272-0054
Mammogram
A mammogram is a low dose x-ray of the breast used to detect and diagnose breast disease, or to provide a baseline reference for later comparison. Multiple images are obtained by different positioning of the breast. The breast compression during mammography is an essential component to produce an optimal diagnostic mammogram. Film mammography units use film to both capture and display the image; digital mammography units use electronic equipment.
A spot compression reduces the thickness of the area of interest and improves contrast and separation of breast tissues.
Noise
Noise is an undesirable background interference or disturbance that affects image quality. The image noise is commonly characterized by the standard deviation of CT numbers in the image of a uniform object (phantom - generally water) relative to the difference in CT numbers between water and air.
Noise is an important limiting factor of CT image quality and is characterized by a grainy appearance, sometimes described as a salt and pepper pattern. Noise as a result of low radiation dose requires a higher tube current (mA) in combination with narrow slices to maintain image noise at an acceptable level.
Omnipaque for Oral Use
Omnipaque (iohexol) is a nonionic, low-osmolar contrast agent and is also available for oral use, offering gastrointestinal (GI) visualization with minimal side effects. Omnipaque has a neutral taste that even kids will drink.
Orally administered iohexol is poorly absorbed from the normal gastrointestinal tract. Omnipaque is well tolerated and absorbed if leakage into the peritoneal cavity occurs.
The recommended dosage of undiluted Omnipaque (at a concentration of for example 350 mg/mL) for computed tomography of the abdomen in adults is 500 mL to 1000 mL, diluted to concentrations of 6 mg/mL to 9 mg/mL. The oral dose should be administered about 20 to 40 minutes prior to the CT scan.

Drug Information and Specification
NAME OF COMPOUND
Iohexol
MANUFACTURER
INDICATION
Bowel opacification
APPLICATION
Oral, rectal
CONCENTRATION
140, 240, 300 or 350 mg iodine
500 - 1000 mL of diluted solution
PREPARATION
Ready-to-use product, dilutable
STORAGE
Protect vials and glass or polymer bottles from strong daylight and direct exposure to sunlight. Do not freeze. Storage at controlled room temperature, 20°-25°C (68°- 77°F);
PRESENTATION
50, 75, 100, 125, 150, 200 or 250mL bottle or +PLUSPAK (polymer bottle)
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Oxilan®
Oxilan® is a radiographic contrast agent used in diagnostic imaging studies. The degree of contrast enhancement is directly related to the iodine content in the administered dose. Dependent on the iodine content, the osmolalities are 2.1 or 2.4 times that of plasma (285 mOsm/kg water).

Drug Information and Specification
NAME OF COMPOUND
Ioxilan
MANUFACTURER
INDICATION
Brain and body computed tomography, urography, angiography
APPLICATION
Intravascular
PHARMACOKINETIC
Renal excretion
CHEMICAL BOND
Nonionic
585 and 695 mosm/kgH2O
IODINE CONCENTRATION
300 and 350 mg/mL
Depending on the used concentration and imaging procedure
PREPARATION
Ready-to-use product
STORAGE
Store between 15° - 30° Celsius (59° - 86° Fahrenheit)
PRESENTATION
50 mL, 100 mL, 150 mL, and 200 mL bottles
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]