Conray®
Conray® is a contrast agent intended for intravascular administration as a diagnostic radiopaque medium. Conray® is rapidly transported through the circulatory system to the kidneys and is excreted unchanged in the urine by glomerular filtration.
See also Ionic Contrast Agents, Contrast Media Injector, Dual-Head CT Power Injector, CT Power Injector.

Drug Information and Specification
NAME OF COMPOUND
Iothalamate sodium
DEVELOPER
Mallinckrodt, Inc.
INDICATION
Brain and body computed tomography, urography, angiography
APPLICATION
Intravascular
PHARMACOKINETIC
Renal excretion
CHEMICAL BOND
2300 mosm/kgH2O
IODINE CONCENTRATION
400 mg/mL
1.5 mL/kg
PREPARATION
Ready-to-use product
STORAGE
Store below 30°Celsius (86°Fahrenheit)
PRESENTATION
50 mL vials, 50 mL prefilled plastic syringes
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Convolution
Convolution is an important mathematical technique in digital signal processing. Raw data undergo spatial filtration prior to back projection by combining two signals to form a third signal. Convolution is related to the input signal, the output signal, and the impulse response. This operation is mostly used together with Fourier transformations for CT signal and image processing.
Ethyl Diamine Tetra Acetic Acid
(EDTA) Ethyl diamine tetra acetic acid is used in decontamination applications as well as for the kidney clearance in connection with 99mTc to assign the glomerular kidney filtration.
Intensifying Screen
An intensifying screen is used to intensify the x-ray effect during radiation exposure of the x-ray film. Approximately 5% of the x-ray photons will be absorbed by the film only. Intensifying screens consist of a sheet of inorganic salts that emits fluorescent light when stroked by x-rays. The fluorescent input and output screens of the image intensifier are very similar to intensifying screens.
Calcium tungstate and rare earths are two common salts (also called phosphors) used for intensifying screens. For example, a calcium tungstate (CaWo4) screen can absorb around 40% of the x-ray photons and convert the radiation into light photons. A basic feature of this screen types is related to the position of the k-edge on the energy axis. Tungsten (W) is a heavy element has a k-edge at 69.5 keV, while that for rare earth elements is in around 50 keV.
The fraction of x-rays absorbed by a screen is depending on the speed. Factors affecting the speed of a screen:
the phosphor type;
the x-ray radiation absorption efficiency;
the radiation to light intrinsic conversion efficiency;
the thickness of the screen.
Mammography cassettes contain usually one intensifying screen, but most others use two screens per film cassette. The intensifying screen as part of a film screen system has been an important component in radiology to reduce the radiation dose of the patient. Today, the conventional film cassette is being replaced by an imaging plate used in digital systems.

See also Actinides, Cinefluorography and Added Filtration.
Reno-60®
Reno-60® is radiopaque contrast agent with a wide range of indications. Reno-60 should be at body temperature when injected and may need to be warmed before use. Following intravascular injection, iodinated contrast materials are transported through the bloodstream to the kidneys and excreted by glomerular filtration.

Drug Information and Specification
NAME OF COMPOUND
Diatrizoate meglumine
DEVELOPER
Bracco Diagnostics, Inc.
INDICATION
Urography, angiography, arthrography, brain and body computed tomography
APPLICATION
Intravascular
PHARMACOKINETIC
Renal excretion
CHEMICAL BOND
IODINE CONCENTRATION
282 mg/mL
Depending on imaging procedure
PREPARATION
Ready-to-use product
STORAGE
Store at 20-25° Celsius (68-77° Fahrenheit), protect from light.
PRESENTATION
50 mL vials
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]