Radiology - Technology Information Portal
Monday, 29 April 2024
• Welcome to Radiology-TIP.com!
     • Sign in / Create account
 
 'Focal Spot' p2
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'Focal Spot' found in 1 term [
] and 8 definitions [
]
Result Pages :
Filament
The filament is the source of electrons (cathode) in x-ray tubes. A thin wire (0.1- 0.5 mm, usually tungsten) emits electrons due to thermionic emission, operating in a vacuum and energized with electric current.
A CT tube utilizes a larger filament with larger size of the effective focal spot than a conventional x-ray tube.
Fine Focus X-Ray Tube
A fine focus x-ray tube contains a focal spot smaller than 0.5 millimeters.
Focus to Detector Distance
(FDD) The focus to detector distance is the distance between the focal spot of the x-ray tube and the radiation detectors.
Magnification
Usually, magnification is the enlargement of an area by interpolation after the reconstruction of an image. Magnification does not provide more information, but allows a better view of certain object details. A zoom reconstruction is based on the raw data of the scan. Magnification software enlarges an image by mapping one pixel onto an n x n array of screen pixels (pixel stretching).
Other types of magnification include electron-optical, geometric, the product of geometric and the electron-optical magnification and enlargement by imaging procedures.
Electron-optical magnification is the ratio of the dimension of the detector input image and the size of the image on the screen. This ratio is determined by all electronic and optical imaging processes of the image chain, provided that one camera pixel is mapped onto accurately one monitor pixel.
Geometric magnification occurs in x-ray images when the focal spot is theoretically assumed to be a point and not an area. For nanofocus and microfocus radiographic systems, the focus-to-detector (film) distance and the focus-to-object (film) distance defines the geometric magnification.
The total magnification is the product of the electron-optical and geometric magnification. Possible magnifications are up to a factor of 26,000.
Magnification procedures in medical imaging are usually produced by extended distance between the subject and the image receptor.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]