Acute Radiation Syndrome
(ARS) The acute radiation syndrome is a form of radiation sickness. An acute radiation syndrome can be developed after the exposition to a high radiation dose received in a short period of time (e.g., x-rays or gamma rays). ARS subsyndromes include hematopoietic, cutaneous, gastrointestinal, and neurovascular diseases. The reaction will vary with dose and factors like age, medical co-morbitdity and immunosuppression.
Neutron Activation Analysis
(NAA) Neutron activation analysis is a very sensitive analytical technique to determine even very low concentration of chemical elements, trace elements for example, in small biological samples.
NAA becomes commercial available in the USA in 1960.
In the activation process stable nuclides in the sample, which is placed in a neutron beam (neutron flux, 90-95% are thermal neutron with low energy levels under 0.5 eV), will change to radioactive nuclides through neutron capture (artificial radioactivity). These radioactive nuclides decay by emitting alpha-, beta-particles and gamma-rays with a unique half-life. Qualitative and quantitative analysis of the sample is done with a high-resolution gamma-ray spectrometer.
NAA is subdivided into the following techniques:
Fast NAA (FNAA): about 5% of the total flux consists of fast neutrons (energy above 0.5 MeV). As a consequence the radiation contains more nuclear particles.
Prompt Gamma NAA (PGNAA): gamma rays are measured during neutron activation. For detection of elements with a rapid decay.
Delayed Gamma NAA (DGNAA): conventional detection after the neutron activation.
Epithermal NAA (ENAA): ~ 2% of the total neutron flux with an energy level between 0.5 eV and 0.5 MeV are detected inside a cadmium or boron shield.
Instrumental NAA (INAA): automated from sample handling to data processing. Analyzes simultaneously more than thirty elements in most samples without chemical processing.
Radiochemical NAA (RNAA): After neutron activation the sample is chemically refined for better analysis.
Roentgen
(R) R is a unit to express exposure to radiation (x-rays or gamma rays). 1 R corresponds to the generation of approximately 2.08 x109 ion pairs (1 electrostatic unit of charge) (in 1 cm³ of dry air at 0 °C and 760 torr). 1 R, converted to SI, equals 2.58 x10-4 coulombs per kg of air.
Brachytherapy
(Radioactive Seed Implantation Therapy) Brachytherapy is a type of radiation therapy in which a sealed source (encapsulated radionuclide) is placed inside the patient as close as possible to the area being treated. The brachytherapy source delivers usually gamma or beta radiation at a distance up to a few centimeters either by surface, intracavitary or interstitial application.

See also Low Dose Rate, Cryotherapy, RF Thermal Ablation and Prostate Ultrasound.
Gamma Camera
(Scintillation Camera, Scintillation Gamma Camera, Gamma Scintillation Camera or Anger Gamma Camera) A gamma camera is an imaging device used in nuclear medicine to scan patients who have been injected, inhaled, or ingested with small amounts of radioactive materials emitting gamma rays. The gamma camera records the quantity and distribution of the radionuclide that is attracted to a specific organ or tissue of interest.
The first gamma camera was developed and introduced by Hal O. Anger in 1957/58. The structure hasn't changed by today. A gamma camera consists of:
a collimator, usually a multihole collimator;
detector crystals, typically thallium-activated NaI scintillation crystal are used;
photomultiplier tube array
shielding to minimize background radiation
position logic circuits
and the data analysis computer

Through this design the simultaneous registration of gamma ray photons is possible, the computer further allows dynamic imaging.

See also Pinhole, Elution, Center of Rotation, First Pass Scintigraphy, and Anger Hal Oscar.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]