Radiology - Technology Information Portal
Sunday, 12 May 2024
• Welcome to Radiology-TIP.com!
     • Sign in / Create account
 
 'Photon' p7
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'Photon' found in 2 terms [
] and 44 definitions [
]
Result Pages :
...
...
Effective Energy
The effective energy (related to bremsstrahlung radiation from an x-ray machine) is the monoenergetic photon energy which produces the same first half value layer in a given material as the x-ray beam.
Electron Excitation
Electron excitation is the discrete energy storage in an orbital electron. The excitation energy results from the absorption of a photon (photoexcitation) or from the absorption of another electron (electrical excitation). The absorbed energy lifts the electron to a higher energy level. This process ends with electron relaxation.

See also Electron Relaxation.
Electron Relaxation
Electron relaxation is the release of a short time stored discrete energy by an orbital electron which will then falls back to a lower energy level. The energy difference is emitted by the electron as a photon or given to another particle.

See also Electron Excitation.
Energy
In physics, energy is described as the ability to do work by a force, measured in joules (J).
Several different forms of energy exist to describe various natural phenomena.

See also Photon Energy, Rest Energy, Binding Energy, Kinetic Energy and Effective Energy.
Gamma Camera
(Scintillation Camera, Scintillation Gamma Camera, Gamma Scintillation Camera or Anger Gamma Camera) A gamma camera is an imaging device used in nuclear medicine to scan patients who have been injected, inhaled, or ingested with small amounts of radioactive materials emitting gamma rays. The gamma camera records the quantity and distribution of the radionuclide that is attracted to a specific organ or tissue of interest.
The first gamma camera was developed and introduced by Hal O. Anger in 1957/58. The structure hasn't changed by today. A gamma camera consists of:
a collimator, usually a multihole collimator;
detector crystals, typically thallium-activated NaI scintillation crystal are used;
photomultiplier tube array
shielding to minimize background radiation
position logic circuits
and the data analysis computer

Through this design the simultaneous registration of gamma ray photons is possible, the computer further allows dynamic imaging.

See also Pinhole, Elution, Center of Rotation, First Pass Scintigraphy, and Anger Hal Oscar.
Result Pages :
...
...
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising