Radiology - Technology Information Portal
Friday, 3 May 2024
• Welcome to Radiology-TIP.com!
     • Sign in / Create account
 
 'X-Ray Film' p4
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'X-Ray Film' found in 1 term [
] and 10 definitions [
], (+ 9 Boolean[
] results
Result Pages :
Mammogram
A mammogram is a low dose x-ray of the breast used to detect and diagnose breast disease, or to provide a baseline reference for later comparison. Multiple images are obtained by different positioning of the breast. The breast compression during mammography is an essential component to produce an optimal diagnostic mammogram. Film mammography units use film to both capture and display the image; digital mammography units use electronic equipment.
A spot compression reduces the thickness of the area of interest and improves contrast and separation of breast tissues.
• 
View NEWS results for 'Mammogram' (1).Open this link in a new window.
Arthrogram
An arthrogram is an x-ray fluoroscopy of a joint performed with a sequential digital subtracted spot films after injection of a contrast agent.

See Arthrography.
Imaging Plate
An imaging plate is used in computed radiography (CR) instead of a conventional film cassette.
The imaging plate is coated with photostimulable phosphors. The phosphor layer is doped with special substances to alter the crystalline structure and physical properties. After radiation, the enhanced phosphor material absorbs and stores x-ray energy in gaps of the crystal structure, building a latent image.
Usually, the storage phosphors are stimulated with a low-energy laser to release visible light at each point of x-ray absorption. To read-out the image, the plate is inserted into a computed radiography scanner. The scanning laser beam causes the electrons to relax to lower energy levels, emitting light that is captured by a photo-multiplier tube and converted into an electrical signal. The electronic signal is then converted to digital data and can be displayed on laser-printed films, workstations, transmitted to remote systems, and stored digitally.
The CR units automatically erase the image plate after the complete scan. Phosphor imaging plates, like film, are stored in cassette format and can be re-used very often if they are handled carefully. Existing conventional x-ray equipment, from generators to x-ray tubes and examination systems, can be used with imaging plates.
Conventional Radiography
Conventional (also called analog, plain-film or projectional) radiography is a fundamental diagnostic imaging tool in the detection and diagnosis of diseases. X-rays reveal differences in tissue structures using attenuation or absorption of x-ray photons by materials with high density (like calcium-rich bones).
Basically, a projection or conventional radiograph shows differences between bones, air and sometimes fat, which makes it particularly useful to asses bone conditions and chest pathologies. Low natural contrast between adjacent structures of similar radiographic density requires the use of contrast media to enhance the contrast.
In conventional radiography, the patient is placed between an x-ray tube and a film or detector, sensitive for x-rays. The choice of film and intensifying screen (which indirectly exposes the film) influence the contrast resolution and spatial resolution. Chemicals are needed to process the film and are often the source of errors and retakes. The result is a fixed image that is difficult to manipulate after radiation exposure. The images may be also visualized on fluoroscopic screens, movies or computer monitors.
X-rays emerge as a diverging conical beam from the focal spot of the x-ray tube. For this reason, the radiographic projection produces a variable degree of distortion. This effect decreases with increased source to object distance relative to the object to film distance, and by using a collimator, which let through parallel x-rays only.
Conventional radiography has the disadvantage of a lower contrast resolution. Compared with computed tomography (CT) and magnetic resonance imaging (MRI), it has the advantage of a higher spatial resolution, is inexpensive, easy to use, and widely available. Conventional radiography can give high quality results if the technique selected is proper and adequate. X-ray systems and radioactive isotopes such as Iridium-192 and Cobalt-60 for generating penetrating radiation, are also used in non-destructive testing.

See also Computed Radiography and Digital Radiography.
Direct Exposure Film
Direct exposure films are highly sensitive to the direct effect of x-rays rather than in combination with an intensifying screen. However, a film is a relatively inefficient radiation detector and requires relatively high radiation exposure. The use of rectangular collimation and the highest speed films reduce radiation exposure.

See also Conventional Radiography.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]