Radiology - Technology Information Portal
Friday, 17 May 2024
• Welcome to Radiology-TIP.com!
     • Sign in / Create account
 
 'My' p4
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'My' found in 5 terms [
] and 16 definitions [
]
Result Pages :
Iodide-Induced Hyperthyroidism
Iodinated contrast media contain small amounts of free iodide. Too much free iodide in the blood may cause hyperthyroidism in patients at risk, but contrast medium induced thyrotoxicosis is rare. The free iodide may also interfere with nuclear medicine diagnostic tests and treatment. However, iodinated contrast agents do not affect thyroid function tests (e.g., T3, T4, TSH) in patients with a normal thyroid.
Guidelines were prepared by the 'Contrast Media Safety Committee of the European Society of Urogenital Radiology' and discussed on the Tenth European Symposium on Urogenital Radiology in September 2003.
Tests of thyroid function before the injection of contrast agents may only be indicated in areas with dietary iodine deficiency. Patients with Graves' disease, multinodular goiter with thyroid autonomy, especially elderly and patients who lives in areas of iodine deficiency are at risk to develop thyrotoxicosis after IV contrast medium and should be monitored by endocrinologists after contrast enhanced CT exams. Prophylaxis may offer some protection in selected high-risk individuals but is not generally recommended.
The free iodide of iodinated contrast agents interferes with thyroidal iodide uptake and impedes diagnostic thyroid scintigraphy and radio-iodine treatment of thyroid malignancies for 2 months after administration.
Isovist®
Isovist® is a nonionic x-ray contrast agent. Isovist® is suitable for intrathecal applications for example CT myelography, cisternography, the evaluation of cerebrospinal fluid (CSF) circulation and for use in other body cavities. Opacification is directly visible after administration of Iotrolan to the spinal subarachnoid space and various open body cavities. Isovist® flows with the CSF through the arachnoid villi into the venous blood.

Drug Information and Specification
NAME OF COMPOUND
Iotrolan
INDICATION
Computed tomography of body cavities and CSF
APPLICATION
Intrathecal, intracavitary
PHARMACOKINETIC
Renal excretion
CHEMICAL BOND
270 or 320 mosm/kgH2O
IODINE CONCENTRATION
240 or 300 mg/mL
5 - 15 mL/kg
PREPARATION
Ready-to-use product
STORAGE
Store below 30°Celsius (86°Fahrenheit)
PRESENTATION
10 and 20 mL vials
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Isovue®
Isovue® is a nonionic contrast agent with a wide range of iodine concentrations.
Isovue-370 with its highest concentration of contrast approved for CT is an excellent agent to match the speed and power of multi-detector row CT (MDCT). Prefilled syringes provide easy and efficient contrast media handling. Isovue-M® is indicated for CT myelography.

See also Contrast Media Injector, Single-Head CT Power Injector, Multi-Head Contrast Media Injector, Syringeless CT Power Injector.
Drug Information and Specification
NAME OF COMPOUND
Iopamidol
DEVELOPER
Bracco Diagnostics, Inc.
INDICATION
Brain and body computed tomography, urography, angiography, phlebography (peripheral venography)
APPLICATION
Intravascular
PHARMACOKINETIC
Renal excretion
CHEMICAL BOND
413, 524, 616 and 796 mosm/kgH2O
IODINE CONCENTRATION
200, 250, 300 and 370 mg/mL
Depending on the concentration: 100 - 200 mL, do not exceed 60 grams of iodine.
PREPARATION
Ready-to-use product
STORAGE
Store at 20-25° Celsius (68-77° Fahrenheit). Protect from light.
PRESENTATION
Depending on the concentration: 20, 30 and 50 vials; 75, 100, 125, 150, 175 and 200 mL bottles
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Joint Scintigraphy
A joint scintigraphy is a nuclear medical study to detect active joint disease (for example arthritis, osteomyelitis and synovitis). Joint scintigraphies are possible with different radiopharmaceuticals as 99mTc-Tc04, 99mTc nanocolloid (NC) or 99mTc-IgG. Joint scintigraphy is a procedure for a specific purpose rather than a routine test.

See also Bone Scan, Bone Marrow Scintigraphy and Multiphase Bone Scintigraphy.
Nonionic Contrast Agents
Nonionic contrast agents are a group of contrast media that do not dissociate into charged particles. Many of the side effects of contrast agents are due to the injection of a solution with high osmolality compared to blood. Nonionic contrast agents have a low osmolality and tend to have less toxicity. However, as with all iodinated contrast agents, serious or fatal reactions have been associated with their use.
Due to their lower neurotoxicity, nonionic contrast agents can also be used for myelography. The only FDA approved agent, iodixanol, is iso-osmolar to blood, which makes it preferable for examinations of the central nervous system and cardiovascular studies. Because of its higher costs relative to other nonionic agents, the use is sometimes reserved for patients with high risk of nephrotoxicity.

See also Nonionic Dimer, Nonionic Monomer and CM Ratio.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]