Radiology - Technology Information Portal
Friday, 3 May 2024
• Welcome to Radiology-TIP.com!
     • Sign in / Create account
 
 'Data Acquisition' p2
SEARCH   
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
Searchterm 'Data Acquisition' found in 1 term [
] and 5 definitions [
], (+ 5 Boolean[
] results
Result Pages :
Triggering
Method, which synchronize the data acquisition with the heartbeat or respiration.

See also Gating.
CT Angiography
(CTA) A computed tomographic angiography or computerized tomography angiogram is a diagnostic imaging test that combines conventional CT technique with that of traditional angiography to create images of the blood vessels in the body - from brain vessels to arteries of the lungs, kidneys, arms and legs.
High resolution CT scans with thin slices and intravenous injection of iodinated contrast material provide detailed images of vascular anatomy and the adjacent bony structures. CTA requires rapid scanning as the imaging data are typically acquired during the first pass of a bolus of contrast medium. The selection of acquisition timing is important to optimize the contrast enhancement, which is dependent on contrast injection methods, imaging techniques and patient variations in weight, age and health. CT angiography is less invasive compared to conventional angiography and the data can be rendered in three dimensions.

CTA techniques are commonly used to:
Detect pulmonary embolism with computed tomography pulmonary angiography;
rule out coronary artery disease with coronary CT angiography;
evaluate heart disease with cardiac CT;
identify aneurysms, dissections, narrowing, obstruction and other vessel disease in the aorta or major blood vessels;

See also Cardiovascular Imaging, Magnetic Resonance Angiography MRA, Coronary Angiogram, Computed Tomography Dose Index and Computed or Computerized Axial Tomography.
3D Reconstruction
A wide range of software techniques and advanced computer systems are developed that enable creation of three-dimensional images. Spiral CT allows the acquisition of CT data that is perfectly suited to 3D reconstruction. Advanced CT scanners image entire anatomic regions like the lungs in one breath hold and acquire a volume of data with the patient anatomy all in one position. This volume data is reconstructed to provide 3 dimensional pictures of for example complex blood vessels like the renal arteries or aorta. 3D reconstructions allow surgeons to visualize complex fractures in three dimensions and can help them plan reconstructive surgery.
Image Quality
Image quality is an important value of all radiographic imaging procedures. Accurate measures of both image quality and patient radiation risk are needed for effective optimization of diagnostic imaging. Images are acquired for specific purposes, and the result depends on how well this task is performed. The imaging performance is mainly influenced by the imaging procedure, examined object, contrast agents, imaging system, electronic data processing, display, maintenance and the operator. Spatial resolution (sharpness), contrast resolution and sensitivity, artifacts and noise are indicators of image quality.
A high image contrast provides the discrimination between tissues of different densities.
The image resolution states the distinct visibility of linear structures, masses and calcifications.
Noise and artifacts degrade the image quality. In computed tomography (CT), high spatial resolution improves the visibility of small details, but results in increased noise. Increased noise reduces the low contrast detectability. Noise can be reduced by the use of large voxels, increased radiation dose, or an additional smoothing filter, but this type of filter increases blurring.
An image acquisition technique taking these facts into account maximizes the received information content and minimizes the radiation risk or keeps it at a low level.

See also As Low As Reasonably Achievable.
Diagnostic Imaging
Imaging refers to the visual representation of an object. Today, diagnostic imaging uses radiology and other techniques, mostly noninvasive, to create pictures of the human body. Diagnostic radiography studies the anatomy and physiology to diagnose an array of medical conditions. The history of medical diagnostic imaging is in many ways the history of radiology. Many imaging techniques also have scientific and industrial applications. Diagnostic imaging in its widest sense is part of biological science and may include medical photography, microscopy and techniques which are not primarily designed to produce images (e.g., electroencephalography and magnetoencephalography).
Brief overview about important developments:
Imaging used for medical purposes, began after the discovery of x-rays by Konrad Roentgen 1896. The first fifty years of radiological imaging, pictures have been created by focusing x-rays on the examined body part and direct depiction onto a single piece of film inside a special cassette.
In the 1950s, first nuclear medicine studies showed the up-take of very low-level radioactive chemicals in organs, using special gamma cameras. This diagnostic imaging technology allows information of biologic processes in vivo. Today, single photon emission computed tomography (SPECT) and positron emission tomography (PET) play an important role in both clinical research and diagnosis of biochemical and physiologic processes.
In the 1960s, the principals of sonar were applied to diagnostic imaging. Ultrasound has been imported into practically every area of medicine as an important diagnostic tool, and there are great opportunities for its further development. Looking into the future, the grand challenges include targeted contrast imaging, real-time 3D or 4D ultrasound, and molecular imaging. The earliest use of ultrasound contrast agents (USCA) was in 1968.
The introduction of computed tomography (CT/CAT) in the 1970s revolutionized medical imaging with cross sectional images of the human body and high contrast between different types of soft tissues. These developments were made possible by analog to digital converters and computers. First, spiral CT (also called helical), then multislice CT (or multi-detector row CT) technology expanded the clinical applications dramatically.
The first magnetic resonance imaging (MRI) devices were tested on clinical patients in 1980. With technological improvements including higher field strength, more open MRI magnets, faster gradient systems, and novel data-acquisition techniques, MRI is a real-time interactive imaging modality that provides both detailed structural and functional information of the body.

Today, imaging in medicine has been developed to a stage that was inconceivable a century ago, with growing modalities:
x-ray projection imaging, including conventional radiography and digital radiography;
scintigraphy;
single photon emission computed tomography;
positron emission tomography.

All these types of scans are an integral part of modern healthcare. Usually, a radiologist interprets the images. Most clinical studies are acquired by a radiographer or radiologic technologist. In filmless, digital radiology departments all images are acquired and stored on computers. Because of the rapid development of digital imaging modalities, the increasing need for an efficient management leads to the widening of radiology information systems (RIS) and archival of images in digital form in a picture archiving and communication system (PACS). In telemedicine, medical images of MRI scans, x-ray examinations, CT scans and ultrasound pictures are transmitted in real time.

See also Interventional Radiology, Image Quality and CT Scanner.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising