Number of Measurements
The number of measurements is the complete number of attenuation values measured during the acquisition of CT raw data for a single slice or volume.
Algorithm
An algorithm is a computer compatible equation. Computed tomographic algorithms reconstruct a function from its projections. A very large number of measurements are processed with complex mathematical operations to compute cross-sectional images.
Raw Data
Raw data are the values of all measured detector signals during a scan. After calibration for fluctuations in tube output and beam hardening, the attenuation properties of each x-ray signal are accounted and correlated with the ray position. From these data the CT images are reconstructed including the use of mathematical procedures like convolution filtering and back projection.
Raw data can also be used for later reconstruction of additional planes and images by using a different convolution filter, zoom reconstruction, or an alternative CT number scale.

See also Magnification, Archiving, Number of Measurements and Convolution.
Computed Tomography
(CT or CAT scan) Computed tomography is a diagnostic imaging technique, previously also known as computerized axial tomography (CAT), computer-assisted tomography (CAT), computerized tomographic imaging, and reconstructive tomography (RT).
A CT scan is based on the measurement of the amount of energy that a tissue absorbs as a beam of radiation passes through it from a source to a detector. As the patient table moves through the CT scanner, the CT tube rotates within the circular opening and the set of x-ray detectors rotate in synchrony. The narrow, fan-shaped x-ray beam has widths ranging from 1 to 20 mm. The large number of accurate measurements with precisely controlled geometry is transformed by mathematical procedures to image data. Corresponding to CT slices of a certain thickness, a series of two-dimensional cross-sectional images is created.
A CT is acquired in the axial plane, while coronal and sagittal images can be rendered by computer reconstruction. Although a conventional radiography provides higher resolution for bone x-rays, CT can generate much more detailed images of the soft tissues. Contrast agents are often used for enhanced delineation of anatomy and allow additional 3D reconstructions of arteries and veins.
CT scans use a relatively high amount of ionizing radiation compared to conventional x-ray imaging procedures. Due to widespread use of CT imaging in medicine, the exposure to radiation from CT scans is an important issue. To put this into perspective, the FDA considers the risk of absorbed x-rays from CT scans to be very small. Even so, the FDA recommends avoiding unnecessary exposure to radiation during diagnostic imaging procedures, especially for children.
CT is also used in other than medical fields, such as nondestructive testing of materials including rock, bone, ceramic, metal and soft tissue.

See also Contrast Enhanced Computed Tomography.
Osmole
(Osm) A unit of osmotic pressure used in physical chemistry, cell biology, and medicine.
Definition: 1 osmole is the osmotic pressure of a one molar solution (that is, a solution with a concentration of one mole per liter of solvent) of a substance that does not dissociate.
If chemical solutions are separated by a semipermeable membrane (a membrane that resists the passage of dissolved substances but permits the passage of the solvent, usually water), then the solvent will diffuse across the membrane to equalize the concentrations. This process is called osmosis.
Solutions with higher concentrations of dissolved substances are said to have higher osmotic pressure than solutions having lower concentrations; thus the solvent moves from an area of low osmotic pressure to an area of higher osmotic pressure.
Osmotic pressure depends on the total number of dissolved particles, so for a substance that dissociates into two ions, such as ordinary salt (sodium chloride), a one molar solution has an osmotic pressure of 2 osmoles. In practice, most measurements are in milliosmoles (mOsm). Typical values range from 20 mOsm for fresh water through 290 mOsm for typical human blood plasma to 1010 mOsm for salt water from the open ocean.
See also Part Per Million.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn

Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]